Contents and general safety instructions

XVIII

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Term / abbreviation

Meaning

Project zero point (PZ)

Dimension reference point for all positions in positioning tasks. The project
zero point forms the basis for all absolute position specifications (e.g. in the
position set table or in direct mode). The point of reference for the project
zero point is the axis zero point.

Record

Positioning command defined in the position set table, consisting of target
position, positioning mode, speed, acceleration, ...

Reference point (REF)

Point of reference for the incremental measuring system. The reference point
defines a known position within the drive’s travel.

Software end position

Programmable stroke limit (reference point = axis zero point)
Software end position, pos. (upper):
max. limit position in the positive direction (increasing actual values).
Software end position, neg. (lower):
max. limit position in the negative direction (decreasing actual values).

Tab. 0/2: Terms and abbreviations