Festo Контроллер позиционирования CPX-CMAX User Manual

Page 85

Advertising
background image

3. Drive functions

3−23

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Regarding Fig. 3/6:

1 to 3: Setpoint value and actual value curves. The setpoint
value here refers to the reference setpoint value which is genĆ
erated by the trajectory planning.

4 to 6: Enlarged illustration of the control fault and the two
tolerances. The following error tolerance (11 mm) is much
greater than the positioning tolerance (0.1 to 10 mm or 0.004
to 0.394 in).

7: The MC signal determines which tolerance is used.

Overview of parameters involved (see section 5.4.6)

Parameters involved

Description

PNU

Position control

Target setpoint value: Target position

300:02

Output of the reference setpoint value generator − position

ć

1)

Actual value: Actual position

300:01

Current deviation: Position deviation

300:03

Following error tolerance (fixed: 11 mm or 0.43 in)

ć

Positioning tolerance

411:xx or
545

Force control

Target setpoint value: Target force

301:02

Output of the reference setpoint value generator − force

ć

1)

Actual value: Actual force

301:01

Force deviation

301:03

Following error tolerance (fixed: 5 N or 1.12 lbf )

ć

Force tolerance

411:xx
or 552

1)

No parameter defined, but available in trace

Tab. 3/8: Involved following error or tolerance monitoring parameters

Advertising