3. Drive functions

3−30

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

PNU 1173: Limiting values

Index

Description

EI

1)

Unit

Status value

7

Maximum deĆ
celeration
value

Accel.

7

The maximum possible deceleration determined by the
controller. The maximum deceleration value is deterĆ
mined from identification data and depends on the mass,
start and target position.

8

Speed setĆ
point

Speed

6

That is the speed setpoint desired by the user.

9

Maximum
speed

Speed

6

The maximum possible speed determined by the conĆ
troller. This speed is calculated from the acceleration and
deceleration.

10

Target force

Force

3

For force control only: Target force.

11

Maximum
force value

Force

3

That is the maximum possible force which the drive can
produce. This value depends on the mass and direction in
which the force is acting (not for horizontal configurĆ
ation).
Without mass compensation (horizontal), the maximum
force is 90% of the nominal cylinder force.

12

Force ramp
setpoint value

Force
ramp

8

The set ramp specified by the user

13

Force ramp
maximum
value

Force
ramp

8

The maximum force ramp determined by the controller.

14

Starting force

Force

3

For force control only: Starting force (last setpoint value)

1)

Units index

Tab. 3/11: Limiting values