2−12

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

2.2.3

I/O data in the record select operating mode

I/O data: Record select mode

Data

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Output
data

CCON

CPOS

Record
no.

Reserved

Reserved

Input
data

SCON

SPOS

Record
no.

RSB

Primary actual value (actual position,
actual force)

Assignment of the control and status bytes (record select
mode):

Assignment of the control bytes (record select mode)

CCON
Byte 1

B7
OPM2

B6
OPM1

B5
LOCK

B4
ć

B3
RESET

B2
BRAKE

B1
STOP

B0
ENABLE

y

Mode selection

Block
software
access

ć

Reset
fault

Release
brake

Stop

Enable
drive

CPOS
Byte 2

B7
ć

B6
CLEAR

B5
TEACH

B4
JOGN

B3
JOGP

B2
HOM

B1
START

B0
HALT

y

ć

ć

Teach
value

Jog negaĆ
tive

Jog posiĆ
tive

Start
homing

Start
positionĆ
ing task

ć

Record
no.
Byte 3

Byte 3: Record number of the starting record (1 to 64)

res.
Bytes 4
to 8

Reserved = 0