Festo Контроллер позиционирования CPX-CMAX User Manual

Page 373

Advertising
background image

B. Basic controlling principles

B−31

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Effect

Cause

Remedy

Overswing (no or minimum standstill time before MC)

1 2

Ĉ Reduction of the static supĆ

ply pressure in operation
below the permitted tolerĆ
ance limit

Ĉ Mass load too high (or confiĆ

gured mass load too low)

Ĉ Overstressing (setpoint

acceleration too high)

Ĉ Signal filter factor set too

high

Ĉ Amplification gain set too

high

Ĉ Cushioning factor set too low

·

Stabilize supply pressure or
carry out new identification
travel with low supply presĆ
sure (see section B.6.1)

·

Correct mass load

·

Reduce setpoint values (esĆ
pecially acceleration) or carry
out dynamic identification
travel (automatic limiting)

·

Correct the parameter

·

Correct the parameter

·

Correct the parameter

Overswing (no or minimum standstill time before MC)

1 2

Ĉ too high mass load entered

(in some cases causes overĆ
dampened controller)

Ĉ Overstressing (too high,

fast" setpoint values)

·

Reduce mass load

·

Adapt setpoint values or
carry out dynamic identificaĆ
tion travel (automatic
limiting)

1

Setpoint position

2

Actual position

Advertising