5. Parameter

5−65

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

5.4.9

Direct operating mode: Force control

Direct mode force base value force ramp

PNU

PNU: 550

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Force ramp (index = 8)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Force control is not permissible with semi−

SI 1 N/s

1.000

10

100.000

p

rotary drives.

Imperial 1 lbf/s

200

2

22.481

Base value for the force ramp in direct mode. The master transmits a percent value, which is multiĆ
plied by the base value to reach the final setpoint speed.
Depending on PNU 521:03, the corresponding default value is used instead, if necessary.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Direct mode force workpiece mass

PNU

PNU: 551

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Mass (index = 5)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Force control is not permissible with semi−

d

SI 0.1 kg

0

0

20.000

p

rotary drives.

Imperial 1 lb

0

0

4.409

Workpiece mass in force control direct mode.
Depending on PNU 521:03, the corresponding default value is used instead, if necessary.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.