5. Parameter

5−37

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Current warning to be displayed in FCT

PNU

PNU: 226

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Without unit

Default: 0

Minimum: −

Maximum: −

The PNU 226 contains the warning number the FCT is supposed to display. Warnings are not disĆ
played on the CMAX display.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Fault status for FCT

PNU

PNU: 227

Index: 1 ... 89

Max index: 89

Class: Array

Data type: bitarray

Values

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Write:

The bit−encoded error status allows to indicate the exact status of a fault message. The coding
is identical to the coding of the additional information in PNU 203. For the description, see
section 4.3.3.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Filter diagnostic events

PNU

PNU: 228

Index: 1

Max index: 3

Class: Struct

Data type: bitarray

Values

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Write:

0000 0000 0000 0000 0000 0000 0000 xxxx

This setting can be used to define the scope of the records. By default the CMAX records very large
quantities of information. Not all are equally important. Certain information can selectively be exĆ
cluded from the records, see section 4.4. In this way only the most important events are included in
the diagnostic memory. For allocation, see 4.4.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.