1 general parameter structure of the cmax, General parameter structure of the cmax – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 191

Advertising
background image

5. Parameter

5−3

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

5.1

General parameter structure of the CMAX

The CMAX contains a parameter set with the following structure.

Group

Indices

Description

Device data

100 ... 199

Device identification and device−specific
settings, version numbers, identifier
words, etc.

Axis data

Diagnostic data

200 ... 299

Memory for diagnostic events: fault
numbers, fault time, current messages.

Process data

300 ... 399

Current setpoint values and actual values,
status data

Record list

400 ... 499

For record select operating mode.
A record contains all the setpoint value
parameters required for a positioning proĆ
cedure.

Project data

500 ... 529

Basic project settings: Project zero point,
setpoint value limits for position, force,
speed, ...

Setpoint value for Direct
operating

530 ... 599

Data for jogging and direct setpoint specifiĆ
cation for position, force, ...

Default values

600 ... 699

Global default values

Drive configuration

1100 ... 1149 All axis−specific parameters for pneumatic

drives: Cylinder lengths and diameter, valve
type, ...

Controller data

1150 ... 1189 Amplification factors, identification, adaptaĆ

tion.

Commissioning data

1190 ... 1199 Actual configuration, system of measureĆ

ment, data reset ...

Tab. 5/1: Parameter structure

Advertising