Festo Контроллер позиционирования CPX-CMAX User Manual

Page 203

Advertising
background image

5. Parameter

5−15

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

To perform this task, the following default values are defined
first. Force control is not required, the values are not taken
into account.

Parameter

PNU

Value

Comment

Speed

600

1000 (= 1 m/s)

Do not use the maximum possible values
from the identification data

Acceleration

602

1000 (= 1 m/s

2

)

from the identification data.

Braking ramp

603

1000 (= 1 m/s

2

)

Workpiece mass

605

0

(= 0 kg)

No workpiece mass in normal status

Tolerance

606

50

(= 0.5 mm)

Tolerance = 0.5 mm

Tab. 5/11: Example of default values: Specify default values

Record list: All blank fields in the record list do not need to be
parametrised explicitly. The record control bytes 1+2 can be
used as preset.

ReĆ
cord
No.

RCB1 RCB2 RPC

(Low word)

SetĆ
point
value

Pre−
seĆ
lect

Speed Accel. Delay WP

mass

Tolerance Force

ramp

Bit 0
0001
h

Bit 2
0004
h

Bit 3
0008
h

Bit 5
0020h

Bit 6
0040h

Bit 8
0100h

1

C000 0000

h

7500

2

C000 0020

h

14550

120

3

C000 002D

h

20520

400

200

200

250

4

C000 0000

h

2000

Tab. 5/12: Example of default values: Record list

Advertising