A.3.2 exchanging components, A.3.2, Exchanging components – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 329: A−21, Exchange of a component

Advertising
background image

A. Notes on commissioning and service

A−21

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

A.3.2

Exchanging components

Nominal/actual comparison of the hardware configuration

With each new calculation of the controller, a nominal/actual
comparison between the current hardware configuration
(actual configuration) and the setpoint configuration is perĆ
formed.

Setpoint configuration

The setpoint configuration consists of the values for the
drive configuration parametrised by the user.

Actual configuration

The actual configuration consists of values for the hardware
components ascertained during the automatic hardware
recognition.

Exchange of a component

The CMAX identifies an exchange as specified in Tab. A/4.

Component

Component exchanged for component ...

of the same type and size

of another type or size

Cylinder/drive

DGCI: Recognition based on serial
number of the measuring system

DGCI: Recognition based on length and
diameter information in the measuring
system

Other drives: recognition not possible

Other drives: recognition not possible

Valve

Recognition based on serial number

Recognition based on type information

Measuring system

DGCI: Recognition based on serial
number

DGCI: Recognition based on length and
diameter information

Other measuring systems: recognition
not possible

Other measuring systems: recognition
of the design based on sensor interĆ
face, no length information.

Sensor interface

Recognition based on serial number

Recognition based on type information

Tab. A/4: Exchange of a component − recognition by the CMAX

Advertising