B. Basic controlling principles

B−17

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Swivel module DSMI

Parameter

Value

Measuring system type

Prescribed: = Potentiometer

Cylinder length

= 270° ... 275°

Measuring system length

Prescribed: = 290°

Offset axis zero point

Selectable within 5° ... 15°

Cylinder diameter

Selection: 25, 40

1)

Piston rod diameter

0

1)

In the CMAX drives with other diameters will lead to errors here.

Rodless linear drive / Piston rod drive

Parameter

Value

Measuring system type

Selectable: 1. Potentiometer

2. Digital position measuring system

Cylinder length

50 mm ... 10,000 mm

Measuring system length

50 mm ... 10.000 mm

Offset axis zero point

within the max. positioning range

1)

Cylinder diameter

12 mm ... 200 mm

Piston rod diameter

Rodless linear drive: 0
Piston rod drive: smaller than cylinder diameter

1)

max. positioning range: stroke between the hardware end positions. The hardware end positions
describe the range where cylinder and sensor overlap, i.e. where the piston can actually move.
However, the max. positioning range must always be larger than 5 mm.