5 error number and warning numbers, Error number and warning numbers – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 145

Advertising
background image

4. Faults and diagnostics

4−9

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

4.2.5

Error number and warning numbers

Fault group 0 ć configuration error

CPX error group 100 (CPX−MMI: [Configuration error] )

No.

Message

Cause/description

Error handling

Type

1)

01

The nominal configurĆ
ation deviates from
actual configuration

2)

A component on the axis
string does not corres−
pond to the nominal conĆ
figuration:
Ĉ Measuring system or

sensor interface
(type, length).

Ĉ Cylinder (type, length,

diameter).

Ĉ Valve (size).

·

Check component and
replace if necessary or

·

Adopt actual configurĆ
ation (download).

Level: F2
Reset: N
Info: ć

The measuring system
and the valve were exĆ
changed and no longer
correspond to the nomĆ
inal configuration or the
serial numbers have
changed.

·

Check configuration of
the axis. Check for
possible interchange
of two axis strings.

02

Unknown valve type

Connected valve is not
supported.

·

Exchange valve or

·

Update firmware.

Level: F2
Reset: N
Info: ć

03

Unknown cylinder type

Connected cylinder or the
sensor interface is not
supported.

·

Exchange cylinder or
sensor interface or

·

Update firmware.

Level: F2
Reset: N
Info: ć

04

Unknown measuring sysĆ
tem type or unknown
sensor interface

Connected measuring
system or the sensor
interface is not supĆ
ported.

·

Exchange measuring
system or sensor interĆ
face or

·

Update firmware.

Level: F2
Reset: N
Info: ć

1)

Level: fault level, see section 4.2.3
Reset: behaviour upon reset, see section 4.2.4
Info:

ć = no info; x = additional info, see FCT or section 4.3.3

2)

The movement test is reset to avoid tubing errors. The CMAX has C03 status. The movement test
should then be run once more.

Advertising