3. Drive functions

3−16

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Status, action

Sequence or status for ...

opening the brake

closing the brake

Controller is disabled

Brake output (pin 2) = 24 V

Brake output (pin 2) = 0 V

Activate controller simultaĆ
neously

1. Brake output (pin 2) = 24 V
2. Position control with

Set = Actual

3. SCON.ENABLED = 1

1. Position control with

set = actual

2. SCON.ENABLED = 1
3. Brake output (pin 2) = 0 V,

simultaneously force control
with 0 force

Controller is active

Brake output pin 2 = 24 V, simulĆ
taneously switch from force conĆ
trol to position control with stop
and set/actual comparison

1. Brake output (pin 2) = 0 V,

simultaneously stop with set/
actual comparison

2. Force control with 0 force

Disable controller simultaĆ
neously

Brake output pin 2 = 24 V, disĆ
able controller simultaneously
(SCON.ENABLED = 0)

1. Disable controller

(SCON.ENABLED = 0)

2. Brake output pin 2 = 0 V

Tab. 3/3: Behaviour when setting and releasing the brake

Status, action

Sequence or status for ...

Activating the controller

Disabling the controller

Brake is closed

1. Position control with

Set = Actual

2. SCON.ENABLED = 1
3. Force control with 0 force

Disable controller
(SCON.ENABLED = 0)

Brake is open

4. Position control with

Set = Actual

5. SCON.ENABLED = 1

Disable controller
(SCON.ENABLED = 0)

Tab. 3/4: Behaviour for activating and deactivating the controller