1

Target position

2

Reference position

3

Actual position

4

Position tolerance

5

Standstill tolerance

6

Speed tolerance

7

Standstill monitoring
active

8

Motion Complete
(SPOS.MC, B2)

9

Standstill error
(SPOS.STILL)

1

2

3

4

5

6

7

9

8

aJ aA

aJ

Position condition met: Standstill tolerance exited

aA

Speed condition met: Drive moved for 30 ms.

Fig. 3/7:

Standstill monitoring