4 festo parameter channel fpc (function 1), Festo parameter channel fpc (function 1) – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 308

Advertising
background image

6. Parametrisation

6−18

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

6.3.4

Festo Parameter Channel FPC (function 1)

Request control and data bytes

Byte

Contents

Description

8

Function head

Para. control byte

PCB = 1

1= Request request for axis X

9

Para. status byte

PSB = 0

Set status to 0 at start

10

Para. function byte

PFB = 1

Function number = parameter channel

11

Para. length byte

PLB = 0 (reserved)

12

Data bytes

Number of parameters

Number of parameters (permissible: 1 ... 7)

13 ... 19

Parameter 1

Byte 1 ... 7 of parameter 1

20 ... 26

Parameter 2

Byte 1 ... 7 of parameter 2

27 ... 33

Parameter 3

Byte 1 ... 7 of parameter 3

34 ... 40

Parameter 4

Byte 1 ... 7 of parameter 4

41 ... 47

Parameter 5

Byte 1 ... 7 of parameter 5

48 ... 54

Parameter 6

Byte 1 ... 7 of parameter 6

55 ... 61

Parameter 7

Byte 1 ... 7 of parameter 7

Tab. 6/9: Allocation of the module parameters for parameter transmission

The individual parameters are FPC requests, as described in
section 6.1.

Structure of parameter 1 ... 7

TransmisĆ

i

f

byte no. in the parameter

sion of

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Request

Index

Parameter identifier
Bit 00...11: PNU
Bit 12...15: Request ID

32−bit parameter value

Response

Index

Parameter identifier
Bit 00...11: PNU
Bit 12...15: Request ID

32−bit parameter value

Tab. 6/10: Allocation of parameters 1 ... 7