3 special features depending on operating mode, Special features depending on operating mode – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 61

Advertising
background image

2. I/O data and sequence control

2−33

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

2.3.3

Special features depending on operating mode

Operating
mode

Notes on specific features

Record select
mode

TA5: A new record can be started at any time

With this, it is possible for the PLC to initiate a new record at any time
depending on any events. The CMAX automatically handles all setpoint
switching problems.

Direct operating
mode

TA2: The condition that no new record may be processed no longer applies.
TA5: A new positioning task can be started at any time.

Commissioning

ć

Identification

TA2: The condition that no new record may be processed no longer applies.
TA5: Restarting during an active commissioning operation is not possible. For

this reason, this transition isn’t used.

Parametrisation

Parametrising mode is not a positioning mode, but is only meant for transferĆ
ring parameters. Transition T3 is not permissible. The drive, then, cannot switch
to the S4 status.

Tab. 2/5: Special features depending on the operating mode

Advertising