A.3.4 data reset, A.3.4, Data reset – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 333: A−25

Advertising
background image

A. Notes on commissioning and service

A−25

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

A.3.4

Data reset

There are three ways of resetting data in the CMAX, see
Tab. A/5.

Reset

Description

Identification
data reset

Ĉ This function can be performed with the FCT and by the PLC.
Ĉ Only the identification data and the adaptation data are reset. All the other

data is retained.

The data reset is triggered by writing on the commissioning parameter data
reset" PNU 1192:03 = 2.

Axis data reset

Ĉ This function can be performed with the FCT and by the PLC.
Ĉ All user parameters of an axis are reset to the delivery status.
Ĉ The identification data, the adaptation data and the maintenance data of an

axis are reset.

Ĉ The diagnostic memory is retained and it contains the entry data reset".
Ĉ Device data such as device name, operating time are retained.
Ĉ A password is not deleted.
The data reset is triggered by writing on the commissioning parameter data
reset" PNU 1192:3 = 3.

Device data reset

Ĉ This function is only available by CI at the diagnostic interface and can only be

triggered by the FCT. A PLC cannot trigger a device data reset via fieldbus.

Ĉ With this reset the entire CMAX is reset to delivery status. The identification

data, adaptation data and maintenance data of both (level 2) axes and the
shared device data such as device name, operating time etc. are deleted.

Ĉ The diagnostic memory of the axes is deleted.
Ĉ A password specified in the device is deleted.

This is the only way to continue using a device if a set password has been lost.

After the reset it is no longer possible to communicate with the CMAX. The disĆ
play shows 3 flashing dashes −−−". The CPX terminal must be switched off and
then back on again.

Tab. A/5: Types of data reset

When speaking about a data reset in general, this refers to an
axis data reset.

Advertising