5. Parameter

5−13

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Parameter Control

Bit

PNU 403: RPC

PNU 521: DMPC

31

= 0: Record is blocked
= 1: Record is active

is not evaluated

30

= 0: Record is not initialised or deleted
= 1: Record is initialised by user

is not evaluated

0 ... 29

Bitfield, controls acceptance of the default values, see Tab. 5/9.
= 0: Using the default values
= 1: Using the parameter from record select or direct mode

Tab. 5/8: Flag for the parameter control

Parameters used depending on the bit status

Bit

Parameter

Bit = 0

Bit = 1

Record
select
mode

Jog

Position

Force

0

Speed, position

600

406

531

540

ć

1

Force speed

601

406

ć

ć

554

2

Acceleration

602

407

532

541

ć

3

Deceleration

603

408

533

542

ć

4

ć (reserved)

ć

ć

ć

ć

ć

5

Workpiece mass

605

410

536

544

551

6

Position tolerance

606

411

ć

545

ć

7

Force tolerance

607

411

ć

ć

552

8

Force ramp

608

412

ć

ć

550

9 ... 29

ć (reserved)

ć

ć

ć

ć

ć

Tab. 5/9: Parameters used