Festo Контроллер позиционирования CPX-CMAX User Manual

Page 224

Advertising
background image

5. Parameter

5−36

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Time stamp: day of operation .

PNU

PNU: 222

Index: 1 ... 100

Max index: 100

Class: Array

Data type: int32

Values

Days

Default: 0

Minimum: −

Maximum: −

Time of the current operating day in milliseconds at the time when the fault occurs.
This time stamp is not a real−time clock. The time is read from the device data PNU 140 when the
fault occurs.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Current error code on display

PNU

PNU: 224

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Without unit

Default: 0

Minimum: −

Maximum: −

Fault number currently shown on the display. This makes synchronisation between the display in the
FCT and the CMAX possible. It is always the fault that occurred first that is displayed.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Current fault level

PNU

PNU: 225

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Without unit

Default: 0

Minimum: −

Maximum: −

In this way the FCT can display the current status of the CMAX in accordance with section 4.2.3.
The most serious current fault is always responsible for the current fault level.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.