3. Drive functions

3−72

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Setpoint value limitation

The setpoint values are limited according to Tab. 3/25.

Setpoint value limitation

Value

Description

Limit values
(rel/abs, if
necessary)

Error or
warning

Secondary
setpoint,
position

Speed as a percentage of the basic value
(PNU 540 or PN U 600).

0 % ... 100%
0.01 m/s to 10 m/s

No

position

Workpiece mass as a percentage of the basic
value of the workpiece mass (PNU 551 or
PNU 605)

0 % ... 100%
0 kg to 2000 kg

1)

No

Primary setĆ
point, posiĆ
tion

Position.

−10,000 mm to
+10,000 mm

2)

Yes

Secondary
setpoint,
force

Force ramp as a percentage of the basic value of
the force ramp (PNU 550 or PNU 608)

0% ... 100%
10 N/s to 10.000 N/s

No

force

Workpiece mass as a percentage of the basic
value of the workpiece mass (PNU 551 or
PNU 605)

0% ... 100%
0 kg to 2000 kg

1)

No

Primary setĆ
point, force

Force

− 100.000 N to
+100.000 N

2)

Yes

1)

The sum of the tool and workpiece masses must not exceed 2000 kg.

2)

The setpoint values are limited to the software or hardware end positions or the set force limit.

Tab. 3/25: Setpoint value limitation in direct mode