Festo Контроллер позиционирования CPX-CMAX User Manual

Page 275

Advertising
background image

5. Parameter

5−87

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Force control damping time for exact stop

PNU

PNU: 1164

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Time (index = 9)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Force control is not permissible with semi−

SI 1 ms

100

10

1.000

p

rotary drives.

Imperial 1 ms

100

10

1.000

This is the duration the actual value must be within the tolerance window without interruption before
MC is generated.
If the time is too short, an overswing may lead to MC, but the actual force may leave the tolerance
again. If the time is too long, the positioning time is unnecessarily prolonged. With larger drives, we
recommend selecting a longer time.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

ý

After writing, controller recalculation is carried out.

Advertising