5. Parameter

5−61

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Jog mode time slow speed

PNU

PNU: 534

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Time (index = 9)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 1 ms

3.000

0

1.000.000 1 ms

3.000

0

1.000.000

Imperial 1 ms

3.000

0

1.000.000 1 ms

3.000

0

1.000.000

Duration of the slow speed phase.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Jog mode workpiece mass

PNU

PNU: 536

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Mass (index = 5)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0.1 kg

0

0

20.000

1 kg cm

2

0

0

2.000

Imperial 1 lb

0

0

4.409

0.1 lb in

2

0

0

6.834

Workpiece mass during jogging.
Depending on PNU 521:01, the corresponding default value is used instead, if necessary.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.