Festo Контроллер позиционирования CPX-CMAX User Manual

Page 274

Advertising
background image

5. Parameter

5−86

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Force control filter factor

PNU

PNU: 1162

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Amplification (index = 10)

Linear drive

Semi−rotary drive

1)

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0,01

100

10

1.000

0,01

100

10

1.000

Imperial 0,01

100

10

1.000

0,01

100

10

1.000

The signal filter factor can be used to influence the signal noise of the pressure sensors. When inĆ
creasing the factor, the filter becomes faster and consequently the noise lounder. At the same time
phase shift decreases.

1)

Force control is not permissible with semi−rotary drives. However, the parameter is used for standĆ
still control and should not be modified.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

ý

This parameter can be written by FCT without higher−order controller.

ý

After writing, controller recalculation is carried out.

Force control timeout

PNU

PNU: 1163

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Time (index = 9)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Force control is not permissible with semi−

d

SI 1 ms

2.000

0

100.000

p

rotary drives.

Imperial 1 ms

2.000

0

100.000

Time within which the actual force must reach the tolerance window after the force ramp has reached
the target value. This means the time starts when setpoint value generation has elapsed.
If the time is set to 0, no monitoring is carried out.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

ý

After writing, controller recalculation is carried out.

Advertising