4. Faults and diagnostics

4−30

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Fault group 8 ć measuring system error

CPX error group 108 (CPX−MMI: [Encoder error] )

continued

No.

Message

Cause/description

Error handling

Type

1)

84

Reference position of the
measuring system lost

Although the controller
has set the status to
Referenced", the
measuring system/
sensor interface reĆ
ported Not referenced".

·

Reference again.

Level: F2
Reset: N
Info: x

85

Operating voltage of the
measuring system/senĆ
sor interface outside of
the tolerance range (unĆ
dervoltage)

Operating voltage of the
measuring system too
low.

·

Check the power
supply.

·

Check the cables at
the axis string.

Level: F2
Reset: F
Info: x

87

Defective measuring sysĆ
tem cable or measuring
system in the electrical
end−position (potentioĆ
meter)

Faulty measuring system
cable.

·

Check the power
supply.

·

Check the cables at
the axis string.

·

It may be necessary to
switch on/off.

·

Exchange measuring
system or sensor inĆ
terface if necessary.

Level: F2
Reset: N
Info: x

Measuring system in the
electrical end position
(only potentiometer)

·

Move the measuring
system (potentioĆ
meter) away from the
end position.

89

Faulty data contents in
the position measuring
system / sensor interface

The position measuring
system / sensor interĆ
face contains incorrect
or contradictory data.

·

Switch the power
supply off and then on
again.

When the error is sigĆ
naled again:

·

Replace the measurĆ
ing system/sensor inĆ
terface.

·

Check firmware of the
CMAX.

Level: F2
Reset: N
Info: x

1)

Level: fault level, see section 4.2.3; (can alternatively be parametrised as a warning or error)
Reset: behaviour upon reset, see section 4.2.4
Info:

ć = no info; x = additional info, see FCT or section 4.3.3