B.2.2, B−11 – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 353

Advertising
background image

B. Basic controlling principles

B−11

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

B.2.2

Dimension reference system with incremental measuring system

System of units with incremental measuring system

1

b

c

PZ

d

e

TP/AP

USE

2

Positions increasing in size, positive"

travel, right−hand" travel

CZ/AZ

REF

LSE

a

CZ

Cylinder zero point

a

Offset axis zero point
offset (increm sensor:

REF

Reference point, stop

offset (increm. sensor:
to the reference point)

AZ

Axis zero point

b

Offset project zero point

PZ

Project zero point

c

Offset target/actual posiĆ
tion

LSE

Lower software end position

d, e

Offset software end posiĆ
tions:

USE

Upper software end position

1

Effective stroke

TP, AP

Target/actual position

2

Cylinder/axis length

Tab. B/9: Dimension reference system for pneumatic drives with incremental measuring

system (example of homing negative stop)

The axis zero point always has to be on the cylinder zero
point! This is necessary because the controller requires the
absolute piston position within the cylinder.
This means that the vector a must always be specified.

Advertising