Festo Контроллер позиционирования CPX-CMAX User Manual

Page 200

Advertising
background image

5. Parameter

5−12

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Advantages:

ć

Simplifies parametrisation.

The record and direct operating parameters are by default
defined so that the respective default values are used
instead of the parameters. If the default values are
used for the parameters speed, acceleration, decelerĆ
ation, workpiece mass and tolerance, this amounts to
5 x 64 = 320 parameters for 64 records that do not need
to be entered.

ć

Increased data transmission performance.

Since less data is transmitted, the time required for
parametrisation is reduced. This affects serial connections
such as with the FCT, but also fieldbus connections.

When is a default value used?

For each parameter a flag defines whether the default value is
used. If you want the value from the record or the special
parameter to be used, the flag needs to be set to 1. OtherĆ
wise the default value will be used. The following parameters
contain flags for default values:

Positioning type

PNU

Index

Description

Record select mode

403

nn (record no.)

Record Parameter Control (RPC)

Jog

521

01

Direct Mode Parameter Control (DMPC)

Direct mode for position

521

02

Direct Mode Parameter Control (DMPC)

Direct mode for force

521

03

Direct Mode Parameter Control (DMPC)

Tab. 5/7: Control of the default values

Advertising