5. Parameter

5−59

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

5.4.7

Setpoint values for jog mode

Jog mode slow speed

PNU

PNU: 530

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Speed (index = 6)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0,001 m/s

50

10

500

1

°/s

50

10

500

Imperial 0.01 ft/s

15

3

164

1

°/s

50

10

500

Slow speed for jogging.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Jog mode fast speed

PNU

PNU: 531

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Speed (index = 6)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0,001 m/s

200

10

10.000

1

°/s

200

10

10.000

Imperial 0.01 ft/s

65

3

3.281

1

°/s

200

10

10.000

Maximum speed after expiration of the jogging slow speed period.
Depending on PNU 521:01, the corresponding default value is used instead, if necessary.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.