B. Basic controlling principles

B−14

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Case distinction for external measuring systems

Layout

Description

PNU 1130

PNU 1101

Cylinder

Measuring system

PNU 1111

The sensor projects above the cylinder on both sides
Offset to the axis zero point: PNU 1130 >= 0
PNU 1130 + PNU 1101 <= PNU 1111
} Min. permissible lower software end position = 0

Max. permissible upper software end position =
PNU 1101

PNU 1130

PNU 1101

Cylinder

Measuring system

PNU 1111

The cylinder projects above the sensor at the end
Offset to the axis zero point: PNU 1130 >= 0
PNU 1130 + PNU 1101 > PNU 1111
} Min. permissible lower software end position = 0

Max. permissible upper software end position =
PNU 1111 − PNU1130

PNU 1101

Cylinder

Measuring system

PNU 1111

PNU 1130

The cylinder projects above the sensor at the beginning
Offset to the axis zero point: PNU 1130 < 0
| PNU 1130 | + PNU 1111 >= PNU 1101
} Min. permissible lower software end position =

| PNU 1130 |
Max. permissible upper software end position =
PNU1101

PNU 1101

Cylinder

Measuring system

PNU 1111

PNU 1130

The cylinder projects above the sensor on both sides
Offset to the axis zero point: PNU 1130 < 0
| PNU 1130 | + PNU 1111 < PNU 1101
} Min. permissible lower software end position =

| PNU 1130 |
Max. permissible upper software end position =
| PNU 1130 | + PNU 1111

Integrated measuring systems

Layout

Description

PNU 1101

Cylinder

Measuring system

PNU 1111

Cylinder and sensor fully cover each other
DGCI: Offset to the axis zero point: PNU 1130 = 0
DNCI: Offset to the axis zero point: PNU 1130 <= 0
PNU 1111 = PNU 1101
} Min. permissible lower software end position = 0

Max. permissible upper software end position =
PNU 1101

Advertising