2. I/O data and sequence control

2−24

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Assignment of the status bytes (commissioning mode)

SCON
Byte 1

B7
OPM2

B6
OPM1

B5
FCT_MMI

B4
24VL

B3
FAULT

B2
WARN

B1
OPEN

B0
ENABLED

y

Operating mode
acknowledgement

Software
device
control

Load
voltage
applied

Fault

Warning

Operation
enabled

Drive
enabled

SPOS
Byte 2

B7
REF

B6
STILL

B5
DEV

B4
MOV

B3
TEACH

B2
MC

B1
ACK

B0
HALT

y

Drive refĆ
erenced

Standstill
warning

Following
error

Axis is
moving

Acknow−
ledge
Teach

Motion
Complete

Acknow−
ledge
Start

ć

Function
Byte 3

Acknowledgement of the commissioning operation currently being executed.

Progress
Byte 4

When executing a commissioning operation: The progress display in the status data shows to
what degree the function has progressed for long operations.
Display in percent (0% to 100%). There could be jumps in the progress display (e. g. from 24%
to 60%). At the end of the function, the progress counter is set to 255 (0xFF).
When teaching: Teach target, see section 3.2.7.

Primary
actual
value
Bytes
5 to 8

Depending on the parametrisation: Actual position or actual force according to the FHPP setĆ
ting (PNU 523:04 or 523:08) in the set system of units (section B.1).