5. Parameter

5−66

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Direct mode force tolerance force

PNU

PNU: 552

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Force (index = 3)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Force control is not permissible with semi−

SI 1 N

10

1

1.000

p

rotary drives.

Imperial 1 lbf

3

0

225

Tolerance window in force control direct mode.
Depending on PNU 521:03, the corresponding default value is used instead, if necessary.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Direct mode force velocity limit

PNU

PNU: 554

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Speed (index = 6)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Force control is not permissible with semi−

d

SI 0,001 m/s

100

0

500

p

rotary drives.

Imperial 0.01 ft/s

30

0

164

Maximum speed at which the drive travels. If the actual speed reaches this value, the force control
switches to positioning and continues at this speed until it arrives at the workpiece and the speed
reduces or the setpoint force is reached. The default value of 0 deactivates switching to position
control, see section B.8.6.
Depending on PNU 521:03, the corresponding default value is used instead, if necessary.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.