C. Configuration with CPX node

C−4

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

C.1.2 Configuration with STEP 7

This description refers to software version V 5.3.

An appropriate device master file (GSD file) must be installed
for configuration.

Proceed as follows for configuration (see Fig. C/1):

1. Add a DP master system

1 and the CPX terminal 2 to

the CPX−FB13, as per the description.

2. Fill the configuration table with the modules of your CPX

system.
Open the module Festo CPX terminal" (folder\PROFIBUS−
DP\Additional FIELD DEVICES\Valves\...) in the hardware
catalogue.

3 .

There are two entries for the CMAX:

Entry

Description

CPX−CMAX−C1−1 [8 Byte I/8 Byte O]

CMAX with 8 byte I / 8 byte O consistent,
without Failsafe parameters
(occupies 5 byte parametrising data)

1)

CPX−CMAX−C1−1 [8 byte I/8 byte A Failsafe]

CMAX with 8 byte I / 8 byte O consistent,
with Failsafe parameters
(occupies 15 byte parametrising data)

1)

1)

The maximum number of parametrisation data for the CPX terminal is limited to 234.

3. Assign each of the starting addresses in the Properties −

DP slave" window

4 .

This concludes the station selection and configuration.