5. Parameter

5−89

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Identified maximum values

PNU

PNU: 1172

Index: 1

Max index: 6

Class: Array

Data type: int32

Values

See description of the respective index.

Default: 0

Minimum: −

Maximum: −

Maximum values determined during identification.
Index

Value

Direction of travel Unit

1

Acceleration

positive

Acceleration (index 7)

2

Deceleration

positive

Deceleration (index 7)

3

Speed

positive

Speed (index 6)

4

Acceleration

nagative

Acceleration (index 7)

5

Deceleration

negative

Acceleration (index 7)

6

Speed

negative

Speed (index 6)

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.