4. Faults and diagnostics

4−38

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Information and details on the faults (PNU 202)

Info (bit 11 ... 08)

Details (bit 07... 00)

Value Description

Value

Description

0

No information

ć

ć

1

Cause of fault E08
(valve drive or

1

Not specified.

(valve, drive or
measuring system

2

Valve was exchanged.

measuring system
was exchanged)

3

Sensor was exchanged.

4

Valve and sensor were exchanged.

2

Cause of fault E09
(faulty parameter

1

Not specified.

(faulty parameter
in the project)

2

A required parameter is not configured (supply pressure,
basic mass without workpiece, control parameter).

3

The measuring system type does not match the cylinder type.

4

The cylinder length does not match the cylinder type.

5

The measuring system length does not match the cylinder
type.

6

The sensor length must be the same as the cylinder length
with this cylinder type.

7

Offset axis zero point is not permissible for this cylinder
(must be 0).

8

The offset axis zero point is faulty. Permitted range:
−Cylinder length <= offset ANP <=0

9

The cylinder diameter does not match the cylinder type.

10

The measuring system type does not match the cylinder type.

11

Two different valves were configured.

12

The lower software end position is smaller than the lower
hardware end position.

13

The upper software end position is larger than the upper hardĆ
ware end position.

14

The lower software end position is larger than or the same as
the upper software end position.

Advertising