Festo Контроллер позиционирования CPX-CMAX User Manual

Page 41

Advertising
background image

2. I/O data and sequence control

2−13

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Assignment of the status bytes (record select mode)

SCON
Byte 1

B7
OPM2

B6
OPM1

B5
FCT_MMI

B4
24VL

B3
FAULT

B2
WARN

B1
OPEN

B0
ENABLED

y

Operating mode
acknowledgement

Software
device
control

Load
voltage
applied

Fault

Warning

OperĆ
ation
enabled

Drive
enabled

SPOS
Byte 2

B7
REF

B6
STILL

B5
DEV

B4
MOV

B3
TEACH

B2
MC

B1
ACK

B0
HALT

y

Drive refĆ
erenced

Standstill
warning

Following
error

Axis is
moving

Acknow−
ledge
Teach

Motion
Complete

Acknow−
ledge
Start

ć

Record
no.
Byte 3

Acknowledgement of the last started record (1 to 64)
In the case of record chaining, the actual record number always contains the currently
actually executed record number. This changes, then, when the record is switched without
a starting edge.

RSB
Byte 4

B7
ć

B6
ć

B5
XLIM

B4
VLIM

B3
RCE

B2
COM1

B1
RCC

B0
RC1

y

ć

ć

Stroke
limit
reached

Speed
limit
reached

Fault
switching
records

Control
mode
acknowlĆ
edgeĆ
ment

All next
records
switched
to

1.
Switched
to next
record

Primary
actual
value
Bytes 5
to 8

Depending on the parametrisation: Actual position or actual force according to the FHPP
setting (PNU 523:04 or 523:08) in the set system of units (section B.1).

Advertising