6 notes on operation, Notes on operation – Festo Контроллеры двигателя SFC-LAC User Manual
Page 137
5. Commissioning
5−55
Festo GDCP−SFC−LACI−IO−EN en 0812NH
5.6
Notes on operation
Warning
There is a danger of injury.
Electric axes can move suddenly with high force and at
high speed. Collisions can lead to serious injury to human
beings and damage to components.
·
Make sure that nobody can reach into the operating
range of the axes or other connected actuators (e.Ăg.
with a protective grille) and that no objects lie in the
positioning range while the system is still connected to
a power supply.
Caution
Not using the parametrising interface as designated
causes injury to people and material damage
The parametrising interface (RS232) is
Ĉ not electrically isolated and
Ĉ not real−time capable.
It is not intended for permanent connection to PC systems
or as a controller interface.
Controlling the SFC−LACI via RS232 requires, among other
things, a risk assessment by the user, ambient conditions
free of interference and reliability of data transmission e.g.
via the control program of the higher−order control system.
·
Note that control of the SFC−LACI via the RS232 does not
comply with designated use.
·
Use the connection only for parameterising, commissionĆ
ing and diagnosis.