2 activate device control, Activate device control, Setting parameters – Festo Контроллеры двигателя SFC-LAC User Manual

Page 92

Advertising
background image

5. Commissioning

5−10

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Setting parameters

1. Set the following:

ć

Homing method [Homing method]

ć

Search speed for ascertaining the reference point
[Velocity v_rp]

ć

Speed of travel to axis zero point [Velocity v_zp].

2. Accept each setting with OK<Enter>.

The setting will then take effect in the drive.

3. Save the parameter settings in EEPROM with the

[SAVE]

menu command. Only then will the settings be retained if
the power supply is switched off or if there is a power
failure.

5.2.2

Activate device control

·

Enable the control panel so that it can control the
SFC−LACI [HMIĂ=Ăon]. This deactivates at the same time
the controller interface of the SFC−LACI.

Caution
When control via the control panel or FCT is activated
(HMI: on), the drive

cannot be stopped with the STOP

input on the control interface.

Commutation point search:
When the controller is enabled for the first time with the
ENABLE signal or [HMIĂ=Ăon], the drive will spend a few
seconds determining its commutation point (vibrations).

} Settings

Homing paramet.

Homing method
Velocity v_rp
Velocity v_zp
SAVE...

Diagnostic
Positioning
Settings

}

HMI control
LCD adjustment

PLEASE WAIT
COMMUT.–POINT
EVALUATION IS
ACTIVE.