5. Commissioning

5−3

Festo GDCP−SFC−LACI−IO−EN en 0812NH

5.1

Preparations for commissioning

Warning
There is a danger of injury.
Electric axes can move suddenly with high force and at
high speed. Collisions can lead to serious injury to human
beings and damage to components.

·

Make sure that nobody can reach into the operating
range of the axes or other connected actuators (e.Ăg.
with a protective grille) and that no objects lie in the
positioning range while the system is still connected
to a power supply.

For commissioning, the mechanical system must be confiĆ
gured and a measuring reference system must be defined
(see Tab. 1/1). By means of the measuring reference system,
all positions are defined and movement can be made to
them, e.Ăg. with a positioning record from the position set
table.

·

Carry out parametrising and commissioning by means of
the control panel or FCT, as described in the following
chapters and in the FCT/PlugIn help.

·

Check the default settings in the [Diagnostic] menu.

·

Upon completion of commissioning, note the instructions
for operation in the FCT/PlugIn help and in section 5.6.