7 local digital inputs and outputs, Local digital inputs and outputs, Section 3.7 – Festo Контроллеры двигателя SFC-LAC User Manual
Page 61
Advertising
3. Installation
3−19
Festo GDCP−SFC−LACI−IO−EN en 0812NH
3.7
Local digital inputs and outputs
3 4 1
Out1
Out2
In1
In2
3 4 1
3 4 1
3 4 1
Connection
Pin
Function
Output 1
(Out1)
3
Ground (GND)
(Out1)
4
Signal
1
+24 VDC logic voltage output
Output 2
(Out2)
3
Ground (GND)
(Out2)
4
Signal A
1
Signal /A
Input 1
(In1)
3
Ground (GND)
(In1)
4
Proximity sensor contact
1
+24 VDC voltage output for proximity sensor
Input 2
(In2)
3
Ground (GND)
(In2)
4
Proximity sensor contact
1
+24 VDC voltage output for proximity sensor
Advertising