B. Supplementary information

B−37

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Record control byte 1

CI

20EAh

01h...22h

Array

uint8

rw

Description

Record control byte 1
Settings for record selection:
Ĉ Relative/absolute positioning
Ĉ Path generator, standard/energy−optimized

Bit0:

=0 absolute position specification;
=1 relative position specification

Bits1..2: Both =0 standard path generator;

Both =1 energy optimised path generator

Bits3..7: Not used (=0)

Note: The energy optimised path generator enables higher dynamics with less
heat, the parametrised positioning curve (a trapeze) is not maintained exactly.
The parametrised maximum values for speed and acceleration may be slightly
exceeded.

Record 0

01h

Do not use (Homing)

Record ...

(positioning

...

(positioning

record ...) Record control byte 1 Positioning record 1...30

Record 31

20h

Record control byte 1 Positioning record 31

Jog mode

21h

Record control byte 1 for jog mode

Direct mode

22h

Record control byte 1 for direct mode

Note: The object 20E0h/01h is provided for access via CI.