B. Supplementary information

B−27

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Diagnostic event

CI

20C8h

01h...10h

Array

uint8

r

Description

Type of fault or diagnostic information saved in the diagnostic memory.
Displays whether an incoming or outgoing fault is saved.
Value

Type of diagnostic event

0 (0x00)

No fault (or diagnostic message deleted)

1 (0x01)

Incoming fault

2 (0x02)

Outgoing fault

3 (0x03)

(reserved)

4 (0x04)

Overrun time stamp

Event 1

01h

Active diagnostic event

Event 2

02h

Previous diagnostic event

Event ...

...

...

Event 16

10h

Oldest saved diagnostic event

Fault number

CI

20C9h

01h...10h

Array

uint16

r

Description

Fault number saved in the diagnostic memory, serves for identifying the fault.
Fault numbers with descriptions: see section 6.4.

Event ...

...

See 20C8h.