Festo Контроллеры двигателя SFC-LAC User Manual
Page 49
![background image](/manuals/464475/49/background.png)
3. Installation
3−7
Festo GDCP−SFC−LACI−IO−EN en 0812NH
Connection
Pin
Designation
Function
Colour
1)
A1
Load voltage
+48 VDC load
Black, 1
A2
Load voltage
GND load
Black, 2
1
Logic voltage
+24 VDC logic
White
2
Logic voltage
GND logic
Brown
3
Hardware
enable
+24 VDC hardĆ
ware enable
Green
4
FE
FE
3)
ć
2)
5
Hardware
enable
GND hardware
enable
Yellow
ć
Plug housing
FE
3)
Earthing strap
with cable
lug M4
Earth
terminal
(housing)
FE
3)
ć
1)
Wire colours of supply cable KPWR−MC−1−SUB−15HC−...
2)
With cable type KPWR−MC−1−SUB−15HC−... not connected.
3)
Use only one connection; see section 3.3
Tab. 3/3: Power" connection (voltage supply) on the SFC−LACI
Caution
Damage to the device
The load voltage supply input has no special protection
against overvoltage.
·
Make sure the permissible voltage tolerance is never
exceeded; see Tab. 3/4.