B. Supplementary information

B−55

Festo GDCP−SFC−LACI−IO−EN en 0812NH

B.2.4

Group 6xxx: Standardised Device Profile Area

Control word

CI

6040h

00h

Var

uint16

w

Description

Modify the current controller status or trigger an activity.
As status modifications require a certain amount of time, all status modificaĆ
tions triggered via the control word must be read back via the status word (obĆ
ject 6041h). Further commands cannot be written via the control word until the
requested status can be read in the status word.
For typical values see Tab. B/6.
After switching off the I/O interface (object 6510/43h), ENABLE OPERATION
should be set to enable the controller when FCT control is being used.

Value

Function

0x000F

ENABLE OPERATION (enable controller)

0x000D

End stage OFF

0x001F

Start ABSOLUTE movement

0x005F

Start RELATIVE movement

0x010F

Stop movement

0x008F

Reset fault + ENABLE OPERATION

0x004F

Set target position as RELATIVE

Tab. B/6: Typical values for the control word