3. Installation

3−20

Festo GDCP−SFC−LACI−IO−EN en 0812NH

3.7.1

Specifications of the outputs

The local digital outputs are supplied by the 24−V logic
voltage (no electrical isolation). They are ESD protected and
short circuit proof, but do not have reverse polarity protecĆ
tion against infeed.

Caution
If 24 V DC voltage is applied and the output pins are used
incorrectly, the device may be seriously damaged. ThereĆ
fore:

·

Do not apply voltage to the outputs.

·

Note the current limitation for the outputs
(max. 1 A permissible per output).

Special features of output 1 (Out1)

ć

Standard PLC output (active high−side switching)

Special features of output 2 (Out2)

ć

Differential output (can be pulse−width modulated)

ć

High− und low−side switching (active full bridge)

ć

It is not used for controlling a PLC, but rather for controlĆ
ling a load, e.g. to control a pulsed motor brake, a valve
or a fan.

The possible uses dependent on the selected pins are deĆ
scribed in section 5.5.5.