A.3 converting the units of measurement, Converting the units of measurement – Festo Контроллеры двигателя SFC-LAC User Manual

Page 161

Advertising
background image

A. Technical appendix

A−7

Festo GDCP−SFC−LACI−IO−EN en 0812NH

A.3

Converting the units of measurement

The CI interface works with increments [Inc, Inc/s,
Inc/s

2

, Inc/s

3

].

DNCE−...−LAS

The distance between two index lines (= north or south pole
of the magnetic displacement encoder) is

5 mm. The resolĆ

ution of the measurement system is 11 bits, which is the
same as 2048

d

(800

h

) increments. The increments are calcuĆ

lated by means of interpolation. This results in the following
conversions (all figures are decimal):

[Inc]

> [mm]

mm

+ xĄInc

2048ĄInc

5Ąmm

[mm]

> [Inc]

Inc

+ xĄmm

5Ąmm

2048ĄInc

DFME−...−LAS

The distance between two index lines (= north or south pole
of the magnetic displacement encoder) is

2 mm. The resolĆ

ution of the measurement system is 11 bits, which is the
same as 2048

d

(800

h

) increments. The increments are calcuĆ

lated by means of interpolation. This results in the following
conversions (all figures are decimal):

[Inc]

> [mm]

mm

+ xĄInc

2048ĄInc

2Ąmm

[mm]

> [Inc]

Inc

+ xĄmm

2Ąmm

2048ĄInc

Advertising