B. Supplementary information

B−73

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Drive data

Homing switch poĆ

larity

6510h

14h

int16

rw

larity

Reference switch type: 0 = N/C contact, 1 = N/O contact

Limit switch deceĆ

leration

6510h

15h

int32

rw

leration

Braking in [m/s

2

] with limit switch signal

Sample input 6510h

16h

uint32

rw

Value = 1: Sampling at IN1; value = 2: sampling at IN2

Brake delay time

switch on

6510h

17h

uint16

rw

switch on

Brake: Switch on delay, see section 5.5.6

Brake delay time

switch off

6510h

18h

uint16

rw

switch off

Brake: Switch−off delay, see section 5.5.6

Automatic brake

time

6510h

19h

uint16

rw

time

Brake: Activation time, see section 5.5.6

PWM delay 6510h

1Ah

uint16

rw

PWM delay, see sections 5.5.5 and 5.5.6.

Output stage

temp

6510h

31h

int16

r

temp.

Temperature of the SFC−LACI output stage. Range: −20...+120 °C

Output stage

max temp

6510h

32h

int16

r

max. temp.

Highest temperature measured to date for the SFC−LACI, in °C. Stored in
EEPROM.

Output stage

lower threshold

6510h

33h

uint16

rw

lower threshold

temp Lower temperature threshold for SFC−LACI: 80 °C

When this temperature is reached, a warning is triggered.

Output stage

upper threshold

6510h

34h

uint16

rw

upper threshold

temp Upper temperature threshold for SFC−LACI: 85 °C. When this temperature is

reached, an error message is triggered. Restart only after the temperature has
dropped below the lower threshold (see subindex 33h).

Max. current

6510h

41h

uint16

rw

Identical to 6073h.

Advertising