B. Supplementary information

B−34

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Position window time

CI

20E6h

01h...22h

Array

uint16

rw

Description

Damping time in milliseconds [ms].
If the actual position has been in the target position window for this amount of
time, the Motion complete" bit is set in the status word. Also referred to as
Adjustment time". Value range: 1 ... 60000 ms. Default: 10 ms.

Record 0

01h

Do not use (Homing)

Record ...

(positioning

...

(positioning

record ...) Damping time for position records 1...30

Record 31

20h

Damping time for position record 31

Jog mode

21h

Damping time with jog mode

Direct mode

22h

Damping time with direct mode

Note: The object 20E0h/07h is provided for access via CI.

6068h contains the damping time of the currently active record.