1 specifications of the controller interface, Specifications of the controller interface, Section 3.6.1) – Festo Контроллеры двигателя SFC-LAC User Manual
Page 60
Advertising
3. Installation
3−18
Festo GDCP−SFC−LACI−IO−EN en 0812NH
3.6.1
Specifications of the controller interface
I/O specification
Signal level
Based on DIN EN 61131, type 1,
positive switching (PNP)
Inputs
Number of digital logic inputs
8
Input current at 24 V input
voltage
Typically > 7 mA
Max. permissible input
voltage
30 V DC
Minimum input voltage
0 V DC
Reverse polarity protection
Yes
Galvanic isolation
Yes
Outputs
Number of digital logic outputs
4
Maximum peak current
0.5 A per output
Overload protection
Yes.
Reversed−polarity voltage must
not be appliedĂ!
Tab. 3/9: I/O specification
Advertising