3. Installation

3−18

Festo GDCP−SFC−LACI−IO−EN en 0812NH

3.6.1

Specifications of the controller interface

I/O specification

Signal level

Based on DIN EN 61131, type 1,
positive switching (PNP)

Inputs

Number of digital logic inputs

8

Input current at 24 V input
voltage

Typically > 7 mA

Max. permissible input
voltage

30 V DC

Minimum input voltage

0 V DC

Reverse polarity protection

Yes

Galvanic isolation

Yes

Outputs

Number of digital logic outputs

4

Maximum peak current

0.5 A per output

Overload protection

Yes.
Reversed−polarity voltage must
not be appliedĂ!

Tab. 3/9: I/O specification