Requirements to be met by the power supply

Voltage

Use

Currents

48 VDC
+5/−10Ă%

Load supply (pins A1, A2)

Nominal current (peak current): 10 A (20 A)
Internal fuse: 16 A slow−blow (external as an option)

24 VDC ±10Ă%

Logic supply (pins 1, 2)

Nominal current (peak current): 0.4 A (0.8 A)
Internal fuse: 4 A slow−blow (external as an option)

Local outputs OUT1/2

Supply via logic supply (pins 1, 2).
Max. 1 A permissible per output.

Hardware enable (pins 3, 5)

Minimum current on contact for the load voltage.

Total

Dependent on the system architecture, up to 3.8 A.

24 VDC ±10Ă%

Supply of the outputs of the conĆ
troller interface
Connection and pin assignment:
see section 3.6.

Idle current: 0.05 A
Peak current (max. 0.5 A per output): 2.1 A

Tab. 3/4: Requirements to be met by the power supply

Example of a power supply connection

1

Connect the
earth terminals
of the two power
supply units.

2

External fuses
(as an option)

3

Switch for
hardware enable

4

Earth terminals
(only use one,
see Ăsection 3.3)

1 2 3 4

A1

5

A2

1

2

3

4

Fig. 3/2:

Power supply connection example