5. Commissioning

5−30

Festo GDCP−SFC−LACI−IO−EN en 0812NH

START: I8

Start positioning record

Note
When using a brake/clamping unit:

·

Observe the special features in conjunction with the
various delay times (see the example for the automatic
brake in section 5.5.6).

The execution of a positioning record is started by a rising
edge at the START input under the following preconditions:

ć

Logic 1 is active at READY.

ć

Logic 1 is at MC.

ć

Logic 1 is active at STOP.

ć

The desired positioning record is active at I1...I5.

Input

Status

START (input)

E8

0

> 1

Start of the positioning record.

The positioning record can be stopped (abort) with a falling
edge at the STOP input. If started again, the positioning reĆ
cord will be continued as from the current position.