6. Diagnostics and error display

6−12

Festo GDCP−SFC−LACI−IO−EN en 0812NH

Error

Fault
no.

*)

Object

Possible cause and remedy

DIGITAL−POWER−
DOWN

Logic voltage < 15 V
Ĉ Voltage drops under load: Power supply too weak,

cable too long, cable cross−section too small?

2FF1h
Bit 6

71

OVERCURRENT
POWER STAGE

Output stage current consumption too high, e.Ăg. due
to short circuit.

·

Contact Festo service.

2FFBh
Bit 1

72

ERROR SFC−LACI
HOT

Temperature >āā 85 °C

·

Remain within all maximum values and check the
mechanical system, e.Ăg. for sluggishness.

·

Reduce the ambient temperature.

·

Improve the heat dissipation.

2FF1h
Bit 5

73

ELGO SENSOR /
COMMUNICATION
ERROR

Position sensor faulty

·

Contact Festo service.

2FF1h
Bit 2

82

CAN
COMMUNICATION
ERROR

CAN communication fault

·

Contact Festo service.

2FF1h
Bit 1

83

i

2

t−ERROR

Current monitoring i

2

t

Possible cause: The drive is blocked, load/dynamics
too high.

·

Check the drive mechanics.

·

Reduce load/dynamic response; increase the
pause times.

2FF1h
Bit 12

100

ERROR MOTOR
HOT

Temperature of the linear motor >āā 75 °C

·

Remain within all maximum values and check the
mechanical system, e.Ăg. for sluggishness.

·

Reduce the ambient temperature.

·

Improve the heat dissipation.

2FF1h
Bit 4

101

MOTOR STOP
ERROR

The positioning procedure is discontinued on the conĆ
trol panel with EMERG.STOP (<Menu> button).

·

Acknowledge the error.

2FF1h
Bit 13

106

HARDWARE
ERROR DRIVE

Wire break on temperature sensor

·

Contact Festo service.

2FF1h
Bit 3

107

*) Fault number in the diagnostic memory, see section 6.3.